National Service Hotline:
+86-372-2595077/2595078/2595088
Purpose
This product is used in the electric-hydraulic control system, together with the proportional amplifier, realizes the control of NG10 proportional value of REXROTH. In the range of the rated stroke and rated current, the output force is proportional to input current. It changes the characteristic force of the system through the internal spring to make output force more stable. Rated current that in infinite speed variation can realize the infinite control and telecontrol of the hydraulic system.
GP63 Series Key Parameters
Code | GP63-S-A | GP63-S-B | GP63-S-C | GP63-S-D |
Rated Current (A) | 3.3 | 2.6 | 2.5 | 3.3 |
Room Temperature Resistance (Ω) | 2 | 4.1 | 3.7 | 2 |
Rated Force (N) | 170 | 170 | 160 | 170 |
Rated Stroke (mm) | 4 | 4 | 4 | 4 |
Total Stroke (mm) | ≥8 | ≥9 | ≥9 | ≥8 |
Force Lag Characteristic (%) | ≤5 | ≤5 | ≤5 | ≤5 |
Current Lag Characteristic (%) | ≤3 | ≤3 | ≤3 | ≤3 |
Repeat Accuracy (%) | ≤1 | ≤1 | ≤1 | ≤1 |
Static Oil Pressure (MPa) | 21 | 21 | 21 | 21 |
Oil Temperature of Work (℃) | -20~+70 | -20~+70 | -20~+70 | -20~+70 |
Protection Grade | IP65 | IP65 | IP65 | IP65 |
Power Connect Mode | Pin Mode | Junction Box Mode |
Key Parameters of Displacement Sensor Screw Proportional Solenoid
Code | GP63-S-BIW | GP63-S-CIW |
Rated Current (A) | 2.6 | 2.5 |
Room Temperature Resistance (Ω) | 4.1 | 3.7 |
Rated Force (N) | 170 | 160 |
Rated Stroke (mm) | 4 | 4 |
Total Stroke (mm) | ≥9 | ≥9 |
Force Lag Characteristic (%) | ≤5 | ≤5 |
Current Lag Characteristic (%) | ≤3 | ≤3 |
Repeat Accuracy (%) | ≤1 | ≤1 |
Static Oil Pressure (MPa) | 21 | 21 |
Oil Temperature of Work (℃) | -20~+70 | -20~+70 |
Protection Grade | IP65 | IP65 |
Power Connect Mode | Pin Mode | Junction Box Mode |
Connector Mark
Externality &Installation Dimensions
GP63Junction Box Mode
GP63Pin Mode
GP63 Series Feedback Junction Box Mode
GP63 Series Feedback Pin Mode
Operating Notice
● There is a protector of over-current between electrical control system and solenoid,in order to prevent the solenoid and the electrical component from burring in improper conditions.
● The handle operating button is fit for adjustment,service and sometime in emergency.
Explanation Of Sample
● If client have special requirements,we can adjust the connect dimension ,power connect method and the extended length of push pin as demanding.