National Service Hotline:
+86-372-2595077/2595078/2595088
Purpose
This series of products is an electro mechanical conversion device that is used in conjunction with proportional control amplifiers in DC 12/24V electro-hydraulic proportional control systems. It can replace imported PPCD04 plug-in proportional electromagnets in parallel. The output force of the electromagnet is converted into displacement through the load spring, achieving linear conversion of current force displacement. It can be installed in any direction. The insulation level of the electromagnetic coil is H, and the protection level is IP67 and P69K. This type of electromagnet is suitable for engineering environments.
Key Parameters
Code | GC29 -2- A 04 |
Rated Voltage (V) | 24 |
Rated Stroke (mm) | 1.2 |
Total Stroke (mm) | ≥1.5 |
Rated Resistance 20℃ (Ω) | 20.8 |
Rated Force (N) | 27 |
Force Lag Characteristic (%) | ≤3 |
Current Lag Characteristic (%) | ≤3 |
Rated Current (A) | 0.75 |
Rated Power (W) | 11.8 |
Stroke-Force Curve
Externality &Installation Dimensions
Operating Notice
● Electromagnet socket standard:DT04-2P。
● There is a protector of over-current between electrical control system and solenoid, in order to prevent thesolenoid and the electrical component from burning in improper conditions.
● The working medium of hydraulic system is mineral oil, phosphoric acid oil.
● Make the vent hole above when installing, make sure the air exhausted from solenoid when you use it.
● The solenoid fit for continuous duty.
Explanation Of Sample
● If the application is beyond the catalogue,please contact with us.
● Characteristic curve for reference only.
● The main performance parameter is obtained in the conditions of lab.Finally explanation and changing of the parameters by KAIDI.